PST-T1110


  

Programmable humidity transmitters - 4-20mA

  • Temperature

  • Relative humidity

  • Dew point temperature

  • Absolute humidity

  • Specific humidity

  • Mixing ratio

  • Specific enthalpy


Programmable temperature and humidity transmitters are equipped with temperature and relative humidity sensors. Measured values are also converted to other humidity interpretation - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy. Transmitters are available in wall-mount, duct-mount and bar types. Also types with RH+T probe on a cable are available. Transmitter contains a microprocessor based control circuitry in a durable plastic case with connection terminals and sensors in a filter with stainless steel mesh. Humidity transmitters are also available with two galvanic isolated 4-20mA outputs. Configuration of outputs and output range are user adjustable. Large dual line LCD for simultaneous display of RH+T or other humidity interpretation is an advantage. Display is possible to switch off. Computerized design ensures temperature compensation of the humidity sensor and fail indication. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitters are designed for use in non-aggressive environment.

 

 

APPLICATIONS - measuring and control of air humidity at:

 

Common Specifications

Operating relative humidity range

0 to 100%

Accuracy of relative humidity measurement

±2.5% relative humidity from 5 to 95% at 23°C

Accuracy of temperature output

±0.4°C from -30 to +100°C

±0.4% from reading over +100°C

Accuracy and range of dew point temperature output

±1.5°C at ambient temperature T<25°C and RH>30%

range -60 to +80 °C

Accuracy and range of absolute humidity output

±3g/m3 at ambient temperature T < 40°C

range 0 to 400 g/m3

Accuracy and range of specific humidity output

±2g/kg at ambient temperature T < 35°C

range 0 to 550 g/kg

Accuracy and range of mixing ratio output

±2g/kg at ambient temperature T < 35°C

range 0 to 995 g/kg

Accuracy and range of specific enthalpy output

±3kJ/kg at ambient temperature T < 25°C

range 0 to 995 kJ/kg

Temperature operating range of case with electronics

-30 to +80°C

Temperature operating range of LCD display

Readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C

Range of humidity sensor temperature compensation

-30 to +125°C

Current outputs - two-wire connection

4-20mA, galvanic isolated with dual-output models

Configuration of outputs and output range

User adjustable from the PC

Filtering ability of sensor cover

0.025mm

Protection of the case with electronics

IP65 electronics, IP40 sensors

Power

9-30Vdc

Warranty

Two years

 

PST-T1110

Measured values

RH

Maximum range of temperature measurement

-30 to +80°C

Length

75 mm

Output 1**

0 to 100% RH

Output 2**

N/A

Notes

Outdoor, indoor use

Only relative humidity output

 

Manual in PDF

* Maximum temperature only at the measuring end with sensors. Maximum temperature +105°C for T3111 with cable probe is allowed also for the cable. Relative humidity at temperature over +85°C is limited in accordance with the graph. Near plastic case with electronics maximum temperature is +80°C.

 

** Any measured value - temperature, relative humidity, dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy can be assigned to each output of dual output transmitters. Also identical value can be assigned to both outputs. Outputs are adjusted to maximum range from the manufacturer. Output range is user adjustable from the PC by means of the optional cable SP003 - see below. Free configuration program for transmitter adjustment is ready to download anytime. If different adjustment of outputs and output ranges are required, please specify required output values (RH, T, Tdp, ..) and required ranges.

Ordering example: Transmitter T3110, output 1: RH 10 to 90%, output 2: temperature 0 to 35°C

Working range of humidity probe

 

Calculation of minimum power voltage Uss for proper operation:

Uss min> Uo min + Imax x Rz,

where: Uo min= 9 V

Imax... approximately 20 mA

Rz... sensing resistor (shunt)

Both current loops (I1 and I2) are connected analogically, current loop I1 must be always connected.

 