PST-T7511
|
|
Programmable humidity transmitters - Ethernet
|
Ethernet sensor is designed for measurement of temperature, barometric pressure, relative humidity, dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy. Degrees Celsius and Fahrenheit are user selectable. Large dual line LCD for simultaneous display of temperature, pressure or relative humidity or other calculated humidity interpretation is an advantage. Display is possible to switch off. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitter is designed for use in non-aggressive environment.
APPLICATIONS - measuring and control of air humidity at:
-
Server rooms
-
Telecommunication devices
-
Warehouses
-
Glasshouses
-
Manufacturers
-
Museums, archives, galleries
-
Air-conditioned rooms
-
Weather stations
|
Modes of communication | |
|
Modbus |
Modbus protocol enables to read measured values, set alarm limits, adjust the probe, read firmware version. |
|
Telnet |
Port 9999 enables to set alarm limits (lower and upper limits for T, RH, Tdp, hysteresis and time delay), e-mail addresses, SNMP addresses, probe description, refresh of www pages (10s to 65535s), select type of www pages, set storing interval to history (10s to 65535s), enable each communication channel. Capacity of the history memory is 100 sets of T+RH+Tdp values. Password protection of this port is enabled. Automatic IP address assignment from DHCP server is also enabled. |
|
WWW pages |
User selectable design of www pages enabling to display curves of measurement history. User can design the look of www pages and select values to display. |
|
SNMP |
It is possible to read actual values and alarm limits. In case of alarm creation warning message (trap) is sent to addresses defined by the user (maximum three addresses). |
|
|
In case of alarm creation warning e-mail message is sent to addresses defined by the user (maximum three addresses). |
|
Common Specifications | |
|
Operating relative humidity range |
0 to 100% |
|
Accuracy of relative humidity measurement |
±2.5% relative humidity from 5 to 95% at 23°C |
|
Accuracy of temperature measurement |
±0.4°C |
|
Accuracy and range of dew point temperature output |
±1.5°C at ambient temperature T<25°C and RH>30% range -60 to +80 °C |
|
Accuracy and range of absolute humidity output |
±3g/m3 at ambient temperature T < 40°C range 0 to 400 g/m3 |
|
Accuracy and range of specific humidity output |
±2g/kg at ambient temperature T < 35°C range 0 to 550 g/kg |
|
Accuracy and range of mixing ratio output |
±2g/kg at ambient temperature T < 35°C range 0 to 995 g/kg |
|
Accuracy and range of specific enthalpy output |
±3kJ/kg at ambient temperature T < 25°C range 0 to 995 kJ/kg |
|
Accuracy and range of barometric pressure output |
± 1.3hPa at 23°C |
|
Supported pressure units |
hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in^2 |
|
Temperature operating range of case with electronics |
-30 to +80°C |
|
Temperature operating range of LCD display |
Readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C |
|
Range of humidity sensor temperature compensation |
-30 to +105°C |
|
Filtering ability of sensor cover |
0.025mm |
|
Protection of the case with electronics |
IP30 electronics, IP40 sensors |
|
LAN connection |
RJ-45 connector |
|
Power |
9-30Vdc, maximum consumption 250mA |
|
Power connector |
co-axial, diameter 5.5 x 2.1 mm |
|
Dimensions of the case (W x H x D) |
88 x 98 x 37 mm |
|
Warranty |
Two years |
PST-T7511
|
Measured values |
Temperature, humidity and barometric pressure |
|
Maximum range of temperature measurement |
-30 to +105°C* probe, cable + 80°C max, optionally with cable up to +105°C |
|
Notes |
Thermometer-hygrometer-barometer
|
* Relative humidity at temperature over +85°C is limited in accordance with the graph. Near plastic case with electronics and probe cable maximum temperature is +80°C.

Working range of Ethernet sensor
Inclusions
-
Calibration certificate from the manufacturer
-
Instruction manual
-
Configuration software (for windows based PC's)