The CNCR-220 is a compact 80 GHz radar level sensor with an extended measuring range up to 49 feet. It features a two-wire 4-20 mA output and is offered with either a 1.5-inch threaded or straight NPT connection. It can measure liquid levels through the tank wall when used on a plastic storage tank or an IBC container. Level measurement data is viewed from a phone or tablet at distances up to 80 feet away, remotely using BinView® software, or on a PLC. The enclosures are rated IP66/IP67, Type 4X to protect them from dust and water ingress. The CNCR-220 performs consistently in condensation, turbulence, and foam. It is suitable for use in many industrial applications along with water and wastewater treatment.
• Environmental control for river, flood, and dam level monitoring or preventing sewer overflows
• Industrial bulk containers (IBC’s), storage tanks, chemical processing, or drums
• Residential drinking water, spring containment, and purified water processing and storage
• Accurate measurement of simple and aggressive liquids in storage and processing tanks up to 49 feet
• Municipal water and wastewater treatment plants, pumping stations, and overflow basins
• Industrial process water, bulk industrial containers, industrial fluids, and wastewater
• Monitoring levels of new and used automotive oils and fluids
• Bulk storage tanks, process and day tanks, cooling towers, and waste sumps
• 80 GHZ non-contact radar technology
• Reliable accuracy within 0.2 inches
• Measuring distance up to 49 feet
• No dead zone, measures to face of sensor
• Installs via a 1.5” threaded or straight NPT connection
• Simple setup and configuration using Bluetooth
• Two-wire 4-20 mA output
• IP66/IP67, Type 4X dust and moisture resistant PVDF enclosure
• FKM seal material for longevity under harsh conditions
Measuring principle: Radar
Measuring range: 49 ft. (15 M)
Frequency: 80 GHz
Beam angle: 8°
Dead zone: None
Accuracy: ≤ 0.2″ (5 mm)
Voltage: 12 to 35VDC
Output: 2-wire 4-20 mA
Enclosure Material: PVDF
Seal Material: FKM
Enclosure Rating: IP66/IP67, Type 4X
Mounting: 1.5″ Threaded NPT, 1.5″ Threaded Straight
Connection: One 1/2″ NPT without plug in either opening
Process Pressure: -14.5 to +43.51 psi (-1 to +3 bar/-100 to +300 kPa)
Process Temperature: -40° to +176°F (-40° to +80°C)
Ambient Temperature: -40° to +158°F (-40° to +70°C)
Approvals: Unclassified area, non-EX environment, general purpose FM/CSA/CE