1300 662 720

Customer Support

1300 662 720

Customer Support

1300 662 720

Customer Support

M1200E | Multi-logger

Multilogger – Low Cost Thermometer with 4 Thermocouple Inputs

Available on back-order

$ 1,225.00 Ex. GST

Share

Share on facebook
Share on twitter
Share on whatsapp
Share on email

M1200E is a battery operated datalogger that allows to monitor the actual measured values on the device display or to work with historical data in Comet Vision, where you can create table charts, PDF export, MS EXCEL.
The device is designed for measuring and recording with 4 inputs for thermocouples K, J, S, B, T, N.
Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

M1200E is a battery operated datalogger that allows to monitor the actual measured values on the device display or to work with historical data in COMET Vision, where you can create table charts, PDF export, MS EXCEL. The device is designed for measuring and recording with 4 inputs for thermocouples K, J, S, B, T, N. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.

Warranty: 3 years

INCLUDED IN DELIVERY

    • M1200E
    • Instruction Manual
    • Traceable Calibration Certificate
    • 3x Alcalic Battery AA
    • USB Cable
    • Wall Holder
    • FREE Analytical Software COMET Vision

EXTERNAL PROBES ARE NOT INCLUDED IN DELIVERY.

MEASURED VALUE

Temperature

TEMPERATURE SENSOR – THERMOCOUPLE K, N

Measuring range -200 to +1300 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR – THERMOCOUPLE J

Measuring range -200 to +750 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR – THERMOCOUPLE S

Measuring range 0 to +1700 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C

TEMPERATURE SENSOR – THERMOCOUPLE B

Measuring range 100 to +1800 °C
Accuracy ± 0,3 % from the measured value + 1 °C in the range +300 to +1800 °C
Resolution 0.1 °C

TEMPERATURE SENSOR – THERMOCOUPLE T

Measuring range -200 to +400 °C
Accuracy ± 0,3 % from the measured value + 1,5 °C
Resolution 0.1 °C
DC VOLTAGE
Measuring range -60 to +140 mV; -18 to +18 mV
Accuracy ±100 µV; ±20 µV
Resolution 0,1 µV

GENERAL TECHNICAL DATA

Operating temperature -10 to +60 °C
Channels 4x external temperature probe
Memory 1 000 000 values (noncyclic record), 600 000 values (cyclic record)
Recording interval 1s to 24 hours
Display and alarm refresh each 10 s
Recording mode noncyclic – data logging stops after filling the memory
cyclic – after filling memory oldest data is overwritten by new
Available temperature units degrees Celsius, degrees Fahrenheit
Communication interface USB
Power 3x AA alkaline battery 1.5 V
Battery life 3 – 4 weeks
Protection class IP20
Dimensions (without connectors) 178 x 95 x 37mm, without attached cables
Weight (including batteries) approx. 380 g
Warranty 3 years

Up to 4 physical Thermocouple Inputs

Multilogger M1200 inputs
  • Themocouple probe K, J, S, B, T, N
  • Direct input of bipolar voltages with range up to -60 to +140 mV
  • Sensors with woltage output (range -60 to +140mV; accuracy ±100 µV or -18 to +18mV; accuracy ±20 µV)

Evaluation of up to 16 variables

Multilogger - LCD detail

Up to 16 variables may be calculated from the four connected probes / sensors. This is the sum of the measured and calculated values. The calculated values can be the result of inter-channel conversions, e.g. the difference of two connected temperature probes. Multilogger LCD display detail.The measured values are stored in the internal non-volatile memory. Memory capacity is up to 1 million values. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory, or cyclic, when after fulfilling the memory oldest stored values are overwritten by new ones.

Measured values are displayed on the screen with backlight option and the ability to change the size of display digits

Power supply

Multilogger - Power Supply
Multilogger - Power Supply

Multilogger can be powered by AC adapter or by rechargeable batteries with charging capability. Batteries are always a part of the device (you can also use standard alkaline AA batteries). Batteries power the device for several months.

While using the AC adapter, the batteries provide backup operations and provide recording and measurement during power failure.

Alarm limits and alarm indication

Multilogger - Alarm limits

It is possible to set two independent alarm limits for each channel (i.e. measured or calculated value).

Alarm signalization can be acoustic (built-in beeper), visual (LEDs, LCD)

Communication interfaces

Multilogger - M1200E

Multilogger is always equipped with USB connector for communication, data analysis and also for charging of the rechargeable batteries.

Insruction Manual

Quick Start Manual

 

CATALOG – Multilogger