LNDS | Liquid Nitrogen Data Logging System

The LNDS is a data logging system for ultra-low temperature monitoring.

Available on back-order

    • 0 $
    • 290 $
    • 0 $
    • 199.5 $
    • 0 $

$ 1,885.50 Ex. GST

Share

Share on facebook
Share on twitter
Share on whatsapp
Share on email

The LNDS Includes:
(1) TCTemp2000: Temperature Data Logger
(1) Type E Thermocouple
(1) 9-Volt AC Power Adapter

The LNDS is an ultra-low temperature measurement system created specifically for monitoring temperature-sensitive materials that need to be preserved at cryogenic temperatures. The probe sheath can record temperatures as low as -200 °C (-328 °F) and are available in a variety of sizes.

Equipped with an LCD screen, the LNDS provides users with the ability to view the current reading, minimum, maximum and average statistics, all in real-time. This device can store 131,071 readings per channel and it’s non-volatile memory provides maximum data security even if AC and battery power are lost.

The LNDS is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

General

Memory 131,071 readings (all channels enabled)
Reading Rate 1 reading every 2 seconds up to 1 reading every 24 hours
Baud Rate 115,200
Cold Junction Compensation Automatic, based on internal channel
Battery Life 1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage. Optional AC Adapter available.
Material Black anodized aluminum
Dimensions 4.8 in x 3.3 in x 1.25 in (122 mm x 84 mm x 32 mm)
Operating Environment -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing
Required Interface Package IFC200 (recommended) or IFC110
Approvals CE

 

Temperature

Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Range -20 °C to +60 °C (-4 °F to +140 °F)
Internal Channel Temperature Resolution 0.1 °C (0.18 °F)
Internal Channel Temperature Calibrated Accuracy ±0.5 °C (±0.9 °F)
Remote Channel Temperature Sensor Type E Thermocouple (included)
Remote Channel Temperature Range -200 °C to +260 °C (-328 °F to +500 °F)
Remote Channel Temperature Resolution 0.1 °C (0.18 °F)
Remote Channel Temperature Calibrated Accuracy ±0.5 °C (±0.9 °F)