Milwaukee MW10 | Digital Free Chlorine Tester

An affordable, pocket-sized free chlorine photometer designed to replace test strips with reliable digital readings. Measures free chlorine from 0.00–2.50 ppm. No calibration required — simply add the DPD reagent, insert the cuvette, and read the result. Suited to aquariums, aquaculture, agriculture, water treatment, labs, and classrooms.

$ 199.50 Ex. GST

2 READY TO SHIP

Availability Info ?
2 AVAILABLE
2 READY TO SHIP, Leaves same day if ordered before 2pm AEST business days.
Need more than 2 items?
Order now and any extra items will be placed on backorder.
Available to back order. ETA will be 6 - 8 weeks.
Shipping Options:

Due to dangerous goods classification, only shipped via Australia Post Road Service. Handling Fee of $25 will be added at the cart. Transit time will be 2 - 7 business days.

Order total:

$199.50 Ex. GST

Description

The Milwaukee MW10 Free Chlorine Photometer lets you go digital with your testing.  No more hit and miss testing with strips.  Great for agriculture, aquariums, aquaculture & coral, labs, water treatment, classroom and more.  This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

Simply add the reagent and get a digital reading accurate to ±0.03 ppm within minutes.

  • Fast, easy-to-read results with large digital LCD readout.
  • Range from 0.00 to 2.50 ppm.
  • Accurate to ±0.03 ppm or ±3% of reading @ 25 °C.
  • Small and ergonomic design.
  • No calibration needed.
  • Reliable and repeatable measurements with no visual assessment.
  • Runs on 1 x AAA battery with auto shut off to extend battery life.
  • Adaptation of the USEPA Method 330.5.  The reaction between Free Clorine and DPD causes a slight pink tint in the sample.
  • Replacement Reagents:  Mi526-100 
  • Replacement cuvetts 2 each:  MI0011

Specifications

  • Range: 0.00 to 2.50 ppm
  • Resolution: 0.01 ppm
  • Accuracy: ±0.03 ppm or ±3% of reading @ 25 °C
  • Typical EMC Dev: ±0.01 ppm
  • Light Source: Light Emitting Diode @ 525 nm
  • Light Detector: Silicon Photocell
  • Method: Adaptation of USEPA method 330.5 – the reaction between free chlorine and the DPD reagent causes a pink tint in the sample.
  • Environment: 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
  • Battery Type: 1 x 1.5V AAA
  • Auto-shut off: After 2 minutes of non-use
  • Meter Dimensions: 3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm)
  • Meter Weight: 0.14 lbs. (0.18 kg)
  • Packaged Dimensions: 4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm)
  • Packaged Weight: 0.4 lbs, (0.18 kg)
  • Replacement Reagents: Mi526-100 (100 tests)