OctVoltV2

The OctVoltV2 is an 8-channel, low-level DC voltage data logger, available in three voltage ranges.

Select your Range

Currently Out of Stock, Backorder only! This item may take 3-4 weeks to deliver. Call us on 1300 662 720

    • 0 $
    • 276 $
    • 0 $
    • 365 $

$ 2,433.00 Ex. GST

Share

Share on facebook
Share on twitter
Share on whatsapp
Share on email

The OctVoltV2 is an 8-channel, low-level DC voltage data logger with a wall mounted power adapter. This device is available in three voltage ranges: 160 mVDC, 3.2 VDC, 32 VDC.

The OctVoltV2 accepts voltage signals from sensors, transducers and many other common voltage sources. It’s capable of measuring and recording up to 174,592 time and date stamped readings. To maximize memory capacity, users can enable or disable channels.

The OctVoltV2 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

OctVoltV2(160mV) —902075-00

OctVoltV2(3.2V) — 902077-00

OctVoltV2(32V) — 902079-00

General

Memory 174,592 readings (all channels enabled)
Reading Rate 4 Hz up to 1 reading every 24 hours
Baud Rate 115,200
Channels 8
LED Indicators 2 (Green/Red)
Battery Life 1 year
Material Anodized aluminum
Dimensions 2.7 in x 7.2 in x 1.3 in (69 mm x 184 mm x 32 mm)
Operating Environment -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing
Required Interface Package IFC200

 

Voltage

Voltage Range ±160 mVDC, ±3.2 VDC, -8 V to +32 V
Voltage Resolution ±160 mVDC: 0.15 µVDC
±3.2 VDC: 0.004 mVDC
-8 V to +32 V: 0.004 mVDC
Voltage Calibrated Accuracy ±160 mVDC: ±0.032 mV (±0.01 % FSR)
±3.2 mVDC: ±0.0032 V (±0.05 % FSR)
-8 V to +32 V: ±0.02 V (±0.05 % FSR)

OctVoltV2 Data Sheet

OctVoltV2 Product User Guide