Milwaukee MW14 | Iron Photometer for Water (0.00-5.00 ppm)

Milwaukee MW14 measures dissolved iron from 0.00 to 5.00 ppm with ±0.04 ppm or ±2% accuracy at 25°C, providing dependable iron concentration data for water treatment facilities, environmental laboratories, and industrial process monitoring where accurate results are essential for quality control and regulatory compliance testing.

$ 199.50 Ex. GST

2 READY TO SHIP

Availability Info ?
2 AVAILABLE
2 READY TO SHIP, Leaves same day if ordered before 2pm AEST business days.
Need more than 2 items?
Order now and any extra items will be placed on backorder.
Available to back order. ETA will be 6 - 8 weeks.
Shipping Options:

Due to dangerous goods classification, only shipped via Australia Post Road Service. Handling Fee of $25 will be added at the cart. Transit time will be 2 - 7 business days.

Order total:

$199.50 Ex. GST

Description

The Milwaukee MW14 High Range Iron Photometer lets you go digital with your testing. No more hit and miss testing with strips.  Great for aquariums, Aquaculture & Coral, labs, water conditioning, classroom and more.  This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

Simply add the reagent and get a digital reading accurate to ±0.04 ppm +/- 2% of reading @ 25°C within minutes.

  • Fast, easy-to-read results with large digital LCD readout.
  • Range from 0.0 to 5.00 ppm.
  • Accurate to ±0.04 ppm or ±2% of reading @ 25 °C.
  • Small and ergonomic design.
  • No calibration needed.
  • Reliable and repeatable measurements with no visual assessment.
  • Adaptation of the USEPA Method Phenatroline 315B.  The reaction between Iron and the reagent causes an orange tint in the sample.  Measures reative (available) iron.
  • Runs on 1 x AAA battery with auto shut off to extend battery life.
  • Replacement cuvetts 2 each:  MI0011
  • Replacement Reagents:  Mi528-25

Specifications

  • Range: 0.00 to 5.00 ppm
  • Resolution: 0.01 ppm
  • Accuracy: ±0.04 ppm or ±2% of reading @ 25 °C
  • Typical EMC Dev: ±0.01 ppm
  • Light Source: Light Emitting Diode @ 525 nm
  • Light Detector: Silicon Photocell
  • Method: Adaptation of USEPA Phenatroline Method 315B – The reaction between Iron and the reagent causes an orange tint in the sample.
  • Environment: 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
  • Battery Type: 1 x 1.5V AAA
  • Auto-shut off: After 2 minutes of non-use
  • Meter Dimensions: 3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm)
  • Meter Weight: 0.14 lbs. (0.18 kg)
  • Packaged Dimensions: 4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm)
  • Packaged Weight: 0.4 lbs, (0.18 kg)
  • Replacement Reagents: Mi528-25 (25 Tests)

Reviews
Leave your review
Rating

Register Your Interest