The complete solution for monitoring of temperature, humidity, pressure, CO2, voltage, current, pulses, events and other signals. Configurable inputs and outputs.

Data loggers are designedย for measuring, recording, evaluationย and subsequent processing ofย input electrical signals,ย which are subject toย relativelyย slow changes (> 1s).ย In conjunctionย with the appropriateย sensorsย andย transducers are suitableย forย monitoringย physical quantities.

The deviceย includesย traceable calibration certificateย with declaredย metrological traceability ofย etalons is based onย requirements ofย ENย ISOย /ย IECย 17025.ย The calibrationย sheetย isย alwaysย loadedย asย modules.

If theย defined requiredย configuration of inputs by, calibration certificateย proves calibrationย inputsย according toย theย required configuration –ย more thanย one range forย each of theย 16 inputs.

INCLUDED IN DELIVERY:
  • MS55D
  • Instruction Manual
  • Traceable Calibration Certificate

EXTERNAL PROBES ARE NOT INCLUDED IN DELIVERY
3 year warranty

MEASURED VALUE
Temperature
Relative humidity
Counted values (dew pointโ€ฆ)
Current
Voltage
Two-state signal
Pulses
Frequency
Resistance
Event logging

GENERAL TECHNICAL DATA
Operating temperatureย 0 to +50 ยฐC
Channelsย 1 to 16 hardware modules
Memoryย 2MB (up to 480 000 values)
Memory typeย internal SRAM, backed-up by Lithium battery
Recording intervalย adjustable individually for all input channels from 1 second to 24 hours
Recording intervalย noncyclic – data logging stops after filling the memory
cyclic – after filling memory oldest data is overwritten by new
Real time clockย year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Resolution of the AD converter (analog channels)ย 16 bits, conversion duration approximately 60ms/channel
Communication speedย 9600, 19200, 57600, 115200 Bd, 230400* Bd (* pro USB, Ethernet)
Powerย 9 to 30Vdc, 24Vdc recommended
Protection classย IP20
Dimensions (including connectors)ย 215 x 225 x 60 mm
Weightย approx. 800 g
Warrantyย 3 years

Device enables:

  • to measure and process 1 to 16 input signals
  • to acquire autonomous time record of measured values
  • create alarm states
  • to perform other actions based on created alarms (audible, visual indication, controlling of relay outputs, sending SMS message, controlling of telephone dialer, sending of messages via several protocols of the Ethernet interface etc.)
  • to monitor on-line measured values and states
  • independent hysteresis setting, delay (for each channel separately)
  • setting up to four alarm conditions (for each channel separately)

Common connectivity options

Monitoring system MS may be configured for almost any desired measurement application. Sensors can be wired to datalogger in star-like connection as well as in serial. Combination of both is also possible.

The monitoring system MS is characterized by a wide range of communication interfaces such as the RS232, RS485, USB, Ethernet and GSM or GPRS modem. Thanks to Wi-Fi routers several measuring systems MS can be wirelessly connected to a network.

  • modular inputs for temperature sensors Pt and Ni, thermocouples and thermistors, voltage and current, two-state events, frequency and pulses, resistance, sensors with RS485 output
  • memory for 500 000 records with automatic downloading to PC
  • alarm indication via integrated siren, e-mail, SMS and two-state output to control other devices
  • software for data analysis on PC
  • communication interface USB, RS232, relays, RS485 (Modbus RTU), ETHERNET (Modbus TCP, SOAP, etc.)