The complete solution for monitoring of temperature, humidity, pressure, CO2, voltage, current, pulses, events and other signals. Configurable inputs and outputs.
Data loggers are designed for measuring, recording, evaluation and subsequent processing of input electrical signals, which are subject to relatively slow changes (> 1s). In conjunction with the appropriate sensors and transducers are suitable for monitoring physical quantities.
The device includes traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO / IEC 17025. The calibration sheet is always loaded as modules.
If the defined required configuration of inputs by, calibration certificate proves calibration inputs according to the required configuration - more than one range for each of the 16 inputs.
INCLUDED IN DELIVERY:MEASURED VALUE
Temperature
Relative humidity
Counted values (dew point…)
Current
Voltage
Two-state signal
Pulses
Frequency
Resistance
Event logging
GENERAL TECHNICAL DATA
Operating temperature 0 to +50 °C
Channels 1 to 16 hardware modules
Memory 2MB (up to 480 000 values)
Memory type internal SRAM, backed-up by Lithium battery
Recording interval adjustable individually for all input channels from 1 second to 24 hours
Recording interval noncyclic – data logging stops after filling the memory
cyclic – after filling memory oldest data is overwritten by new
Real time clock year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Resolution of the AD converter (analog channels) 16 bits, conversion duration approximately 60ms/channel
Communication speed 9600, 19200, 57600, 115200 Bd, 230400* Bd (* pro USB, Ethernet)
Power 9 to 30Vdc, 24Vdc recommended
Protection class IP20
Dimensions (including connectors) 215 x 225 x 60 mm
Weight approx. 800 g
Warranty 3 years
Monitoring system MS may be configured for almost any desired measurement application. Sensors can be wired to datalogger in star-like connection as well as in serial. Combination of both is also possible.