What Is Intrinsic Safety? Intrinsically Safe Equipment Explained

Intrinsically safe data logger and sensor used for monitoring in a hazardous industrial area

Intrinsic safety is a method of explosion protection that limits the electrical and thermal energy in a circuit so it cannot ignite a flammable gas, vapour or dust, even when a fault occurs. Equipment built this way is marked Ex i and is called intrinsically safe. It is the standard approach for low-power instruments such as sensors, transmitters, thermometers and data loggers used in hazardous areas across Australian mining, oil and gas, chemical and grain sites.

Key Takeaways

  • How it works: voltage, current and power are limited so a spark or hot surface cannot reach the minimum ignition energy of the surrounding atmosphere
  • Three levels: Ex ia is safe with two faults applied (Zone 0, 1 and 2), Ex ib with one fault (Zone 1 and 2), Ex ic in normal operation only (Zone 2)
  • Governing standard: IEC 60079-11, adopted in Australia and New Zealand as AS/NZS 60079.11
  • Australian certification: IECEx certificates are accepted almost without exception; ANZEx is the harmonised national scheme; ATEX alone is a European directive, and North American Class and Division approvals need a separate conformity assessment
  • Versus explosion-proof: intrinsic safety prevents the spark; flameproof (Ex d) contains the explosion; increased safety (Ex e) avoids sparks by design
  • Barriers and isolators: a Zener barrier or galvanic isolator in the safe area limits the energy sent into the hazardous area; entity parameters must match between barrier, cable and field device
  • Everyday rule: a normal phone, torch or thermometer cannot be used in a classified zone; only equipment marked and certified for that zone, gas group and temperature class
  • PST range: MadgeTech Temp1000Ex and RHTemp1000Ex data loggers carry ATEX and IECEx intrinsic safety certification for Zones 0 to 2, gas group IIC, temperature class T4, with calibration available from PST’s Pakenham laboratory

Quick answer: key definitions and figures

Intrinsic safety (Ex i) is a protection concept in which the energy available in an electrical circuit is kept below the level that could ignite an explosive atmosphere. Intrinsically safe equipment is equipment designed, tested and certified to that concept. A hazardous area is any place where a flammable gas, vapour, mist or dust may be present in enough quantity to explode. The table below defines the other terms used in this article.

Term Definition
Ex ia, Ex ib, Ex ic The three levels of intrinsic safety. Ex ia stays safe with any two countable faults, Ex ib with one, Ex ic only in normal operation
Zone 0, 1, 2 Gas hazardous area classes: explosive atmosphere present continuously or for long periods (Zone 0), likely in normal operation (Zone 1), or unlikely and short-lived (Zone 2). Zones 20, 21 and 22 are the dust equivalents
Gas group IIA, IIB, IIC Groups gases by how easily they ignite. IIA is typified by propane, IIB by ethylene and IIC by hydrogen and acetylene. IIC equipment covers all three
Temperature class T1 to T6 The maximum surface temperature of the equipment: T1 450 °C, T2 300 °C, T3 200 °C, T4 135 °C, T5 100 °C, T6 85 °C
Equipment protection level (EPL) Ga, Gb and Gc for gas and Da, Db and Dc for dust, from very high to enhanced protection. Ga matches Zone 0, Gb Zone 1 and Gc Zone 2
Associated apparatus A device in the safe area, such as a Zener barrier or galvanic isolator, that limits the energy delivered to the intrinsically safe circuit in the hazardous area
Entity parameters The certified voltage, current, power, capacitance and inductance limits (Uo, Io, Po, Co, Lo on the barrier; Ui, Ii, Pi, Ci, Li on the field device) that must match for a loop to be safe
Simple apparatus A passive or very low energy device, no more than 1.5 V, 100 mA and 25 mW, such as a thermocouple, RTD or switch, that can be used in an intrinsically safe circuit without its own certificate

In short: intrinsic safety keeps circuit energy too low to ignite anything. Choose the level (ia, ib or ic) that matches the zone, check the gas group and temperature class against the site classification, and use IECEx certified equipment in Australia.

What does intrinsically safe mean?

Intrinsically safe means that a piece of electrical equipment, and the circuit it is part of, cannot release enough electrical or thermal energy to ignite a specific explosive atmosphere, even under fault conditions. The energy is limited at the source by design, using current-limiting resistors, voltage clamps and low-power components. Because no spark or hot surface capable of ignition can form, the equipment can be used in classified hazardous areas without a heavy enclosure.

Every flammable gas has a minimum ignition energy, measured in microjoules. Hydrogen needs far less energy than propane, which is why gas groups exist. An intrinsically safe design keeps the worst-case energy in the circuit, including stored energy in cables and capacitors, below that threshold with a safety margin. The certification process applies deliberate faults to the circuit, such as shorted components, to prove the limit holds.

Intrinsic safety suits instruments that need little power: temperature and humidity sensors, pressure transmitters, level switches, handheld thermometers, gas detectors and data loggers. It does not suit motors, heaters or lighting, because those need more energy than the concept allows. For that equipment, other Ex protection methods are used.

Intrinsically safe versus explosion proof: what is the difference?

Intrinsically safe equipment prevents the ignition source from forming. Explosion-proof equipment, called flameproof or Ex d in the IEC system, assumes a spark may occur and contains the resulting explosion inside a strong enclosure. Both are accepted protection concepts, but they solve the problem in opposite ways and suit different equipment.

Intrinsic safety (Ex i) Flameproof (Ex d) Increased safety (Ex e)
Principle Limits energy so no ignition can occur Contains an internal explosion Prevents arcs, sparks and hot surfaces in normal operation
Typical equipment Sensors, transmitters, loggers, thermometers, switches Motors, switchgear, lighting, higher-power devices Terminal and junction boxes, some motors and luminaires
Enclosure Light, often plastic or thin stainless steel Heavy cast enclosure with flame paths Robust but not explosion-containing
Live work in the zone Permitted with conditions, using approved tools and procedures Not permitted; enclosure must be isolated and cooled before opening Not permitted while energised
Zone 0 suitability Yes, at level ia No No
Cost and weight Low High Moderate

What is a hazardous area classification?

A hazardous area classification is a documented assessment of where, how often and for how long an explosive atmosphere may be present on a site. In Australia, it is carried out under AS/NZS 60079.10.1 for gases and vapours and AS/NZS 60079.10.2 for dusts. The result is a set of drawings that divide the plant into zones, and each zone determines the minimum equipment protection level and therefore which intrinsic safety level can be used.

Zone (gas) Zone (dust) Explosive atmosphere is Required EPL Intrinsic safety level
Zone 0 Zone 20 Present continuously or for long periods Ga / Da Ex ia only
Zone 1 Zone 21 Likely to occur in normal operation Gb / Db Ex ia or Ex ib
Zone 2 Zone 22 Not likely in normal operation and, if it occurs, short-lived Gc / Dc Ex ia, Ex ib or Ex ic

The classification also records the gas group and the temperature class the area needs. Equipment marked for a higher group or a lower temperature class can be used in a less demanding area, so IIC T4 equipment can be installed where IIB T3 is required, but not the other way round. The classification is the site operator’s responsibility and is normally prepared by a person holding hazardous area classification competencies.

What is the difference between Ex ia, Ex ib and Ex ic?

The three levels of intrinsic safety differ in how many faults the circuit must survive while staying incapable of ignition. Ex ia must stay safe with any two countable faults applied at once and is the only intrinsic safety level permitted in Zone 0. Ex ib must stay safe with one fault and suits Zones 1 and 2. Ex ic must be safe in normal operation only and is restricted to Zone 2. These levels are defined in IEC 60079-11 and matched to equipment protection levels Ga, Gb and Gc.

Level Faults tolerated Zones permitted EPL Typical use
Ex ia Two countable faults 0, 1 and 2 Ga Critical measurement and shutdown loops; inside tanks and vessels
Ex ib One countable fault 1 and 2 Gb Routine process measurement
Ex ic None (normal operation) 2 only Gc Low-risk monitoring where cost matters

Some instruments are certified across all three levels. PST’s MadgeTech Temp1000Ex and RHTemp1000Ex data loggers, for example, are listed as Ex ia to Ex ic with equipment protection levels Ga to Gc, which means one device can be deployed in any gas zone provided the gas group and temperature class also suit the area.

How do you read an Ex marking?

An Ex marking is read left to right: the Ex symbol, the protection type and level, the gas group, the temperature class and the equipment protection level. A marking of Ex ia IIC T4 Ga means intrinsic safety at level ia, suitable for all gas groups up to hydrogen and acetylene, with a maximum surface temperature of 135 °C, at equipment protection level Ga for Zone 0. Dust markings use the same pattern as Ex ia IIIC and a maximum surface temperature in degrees rather than a T class.

Ex marking decoder explaining equipment group, gas group, temperature class and protection level
How to read a typical Ex marking on intrinsically safe equipment.

How does an intrinsic safety barrier work?

An intrinsic safety barrier sits in the safe area between the control system and the field wiring, and limits the voltage, current and power that can travel into the hazardous area. The field device on its own is not intrinsically safe as a system; it is the combination of the certified field device, the cable and the barrier, with matched entity parameters, that makes the loop safe. Battery-powered instruments such as self-contained data loggers carry their own energy limiting and do not need an external barrier.

Zener barrier versus galvanic isolator

A Zener barrier uses Zener diodes to clamp voltage, a resistor to limit current and a fuse to protect the diodes, and it must be connected to a dedicated intrinsically safe earth. A galvanic isolator uses transformers or optocouplers to separate the hazardous area circuit from the safe area circuit entirely, so no IS earth is needed. Isolators cost more but remove the earth-quality risk and tolerate signal problems better.

Zener (shunt-diode) barrier Galvanic isolator
How it limits energy Diodes clamp voltage, resistor limits current, fuse protects the diodes Transformer or optical isolation with an energy-limited output stage
IS earth required Yes, a dedicated low-resistance IS earth No
Signal accuracy Series resistance can affect readings Isolated output, no ground loops
Cost Lower Higher
Best for Simple loops with a reliable IS earth Sites with earthing problems, high-accuracy signals, multiple loops

Entity parameters and simple apparatus

The entity concept, defined in IEC 60079-11, lets certified barriers and field devices from different makers be combined without testing the whole system. The barrier’s output values (Uo, Io, Po) must not exceed the field device’s input values (Ui, Ii, Pi), and the cable’s capacitance and inductance plus the device’s Ci and Li must stay within Co and Lo. Simple apparatus, meaning passive devices that do not generate or store more than 1.5 V, 100 mA and 25 mW, such as thermocouples, RTDs and dry contact switches, can be used in a certified IS loop without a certificate of their own, although the loop must still be documented.

What standards and certifications apply in Australia?

In Australia, intrinsic safety is governed by the AS/NZS 60079 series, which adopts the international IEC 60079 series. AS/NZS 60079.11 covers intrinsic safety for equipment, AS/NZS 60079.25 covers intrinsically safe systems, AS/NZS 60079.0 covers the general requirements, AS/NZS 60079.10.1 covers area classification, AS/NZS 60079.14 covers installation, and AS/NZS 60079.17 covers inspection and maintenance. Equipment certified under the international IECEx scheme can be used in Australia almost without exception, and the national ANZEx scheme is fully harmonised with it.

Two points catch buyers out. First, a CE mark and an ATEX number on their own are not an Australian certification; ATEX is a European directive, and Australian site operators will look for a current IECEx or ANZEx certificate of conformity. Second, Queensland’s Resources Safety and Health regulator notes that Australia generally does not recognise the North American Class and Division system, so equipment with only FM or UL Class I Division 1 approvals needs a conformity assessment document before it can be installed in a classified area.

Installation and inspection must also be done by people holding the relevant hazardous area competencies, and the installation is recorded in a verification dossier under AS/NZS 60079.14. Buying certified equipment is only the first step.

Is intrinsically safe the same as ATEX or IECEx?

No. Intrinsically safe describes the protection concept. ATEX and IECEx describe how the equipment was certified. ATEX is the European Union directive for equipment in explosive atmospheres. IECEx is the international certification scheme based on IEC standards, and it is the one accepted in Australia. A device can be intrinsically safe and certified under ATEX, IECEx, both, or a national scheme such as ANZEx or FM.

What equipment needs to be intrinsically safe?

Any electrical equipment taken into or installed in a classified zone must carry a protection concept suited to that zone, and for low-power instruments that concept is usually intrinsic safety. This includes fixed sensors and transmitters, portable thermometers and gas detectors, data loggers left in tanks or process areas, radios, torches, tablets and phones. A standard consumer phone or thermometer cannot be used in a hazardous area because its battery, display and circuits are not energy limited or certified.

Typical Australian applications include monitoring temperature inside storage tanks and silos, recording conditions during ethylene oxide sterilisation, logging humidity in paint and solvent stores, and tracking process temperatures in grain handling, mining, oil and gas and chemical plants. In each case, the instrument is chosen against the zone, gas or dust group and temperature class on the site classification drawings.

Intrinsically safe data loggers from Pacific Sensor Technologies

PST supplies MadgeTech intrinsically safe data loggers for hazardous area temperature and humidity monitoring in Australia. According to their product pages, the Temp1000Ex temperature logger and the RHTemp1000Ex temperature and humidity logger carry ATEX and IECEx certification for intrinsic safety Ex ia to Ex ic, equipment protection levels Ga to Gc, Zones 0 to 2, gas group IIC and temperature class T4. Both record from minus 40 °C to 80 °C with a stated accuracy of plus or minus 0.5 °C between 0 °C and 50 °C, store up to 32,767 readings and download through MadgeTech 4 software.

The earlier Temp1000IS and RHTemp1000IS models carry Factory Mutual Class I Division 1 approvals rather than IECEx. For an Australian classified area, the Ex models are the direct fit; the IS models would need a conformity assessment document before use in a zone. Confirm the current certificate and any special conditions on the product page before ordering.

Because intrinsic safety depends on the device staying exactly as certified, treat these loggers differently from standard ones: use only the specified battery, do not open the housing in the zone, keep the case sealed, and have calibration performed outside the hazardous area. PST’s calibration laboratory in Pakenham, Victoria, provides NATA-endorsed calibration for instruments within the scope of NATA Accreditation Number 21142 and traceable calibration for other instruments.

How to select intrinsically safe equipment

Work from the site classification, not from the product catalogue:

  1. Identify the zone, gas or dust group and temperature class from the hazardous area classification drawings.

  2. Choose the intrinsic safety level the zone requires: ia for Zone 0, ib or ia for Zone 1, any level for Zone 2.

  3. Confirm the equipment’s gas group and temperature class cover the area; for example, IIC T4 covers a IIB T3 requirement.

  4. Check for an IECEx or ANZEx certificate of conformity, and read any special conditions of use marked with an X.

  5. For loop-powered devices, match entity parameters between the field device, the cable and the barrier or isolator. For self-contained battery devices, confirm the certificate covers the battery type.

  6. Check the ambient temperature range, ingress protection and any limits on submersion or cleaning.

  7. Plan installation, inspection and calibration with people holding the relevant competencies, and keep the verification dossier up to date.

Conclusion

Intrinsic safety keeps the energy in a circuit too low to ignite an explosive atmosphere, which makes it the natural protection concept for sensors, thermometers and data loggers in hazardous areas. Selecting the right equipment means reading the site classification first, matching the Ex level, gas group and temperature class, and insisting on an IECEx or ANZEx certificate rather than a CE mark alone.

Talk to the Pacific Sensor Technologies team on 1300 662 720 or contact us online about the Temp1000Ex and RHTemp1000Ex intrinsically safe data loggers, their certificates and calibration for your hazardous area monitoring.

Frequently Asked Questions

Can you use a normal phone or thermometer in a hazardous area?

No. Consumer phones, torches and thermometers are not energy limited or certified, so they can be an ignition source. In a classified zone, only equipment marked and certified for that zone, gas group and temperature class may be used. Intrinsically safe phones, tablets and infrared thermometers are available for this purpose.

Yes, with conditions. Because an intrinsically safe circuit cannot produce an ignitable spark even when a wire is disconnected, live calibration and fault finding are permitted under the installation standard, provided approved test instruments are used, and site procedures are followed. This is one of the main practical advantages over flameproof equipment.

No. A self-contained, battery-powered device such as the Temp1000Ex has its energy limiting built in and is certified as a complete unit. Barriers and isolators are needed for loop-powered instruments that receive power from the safe area.

T4 means the hottest surface on the equipment will not exceed 135 °C under the tested conditions. The area classification specifies the T class needed based on the auto-ignition temperature of the gases present. A lower T number allows a hotter surface; T6, at 85 °C, is the strictest.

Certification is issued by accredited Ex certification bodies operating under the IECEx scheme or the national ANZEx scheme. In Australia, TestSafe Australia, a NSW Government laboratory, is an accredited certification body and testing laboratory for both schemes. Equipment with an IECEx certificate of conformity is accepted on Australian sites almost without exception, so most manufacturers certify under IECEx rather than ANZEx alone.