Salinity meters — also called salt meters or NaCl testers — are precision instruments that measure the concentration of dissolved salts in water and liquid samples. Whether you’re managing a saltwater aquaculture pond, testing a pool’s salt-chlorinator system, monitoring seawater quality, or ensuring food products meet sodium specifications, the right salinity meter delivers fast, accurate results in the field or laboratory.
Pacific Sensor Technologies offers a comprehensive range of salinity testing solutions across all form factors: pocket-sized pen testers for quick spot checks, portable meters with data-logging capability for field surveys, analogue and digital refractometers for seawater and food applications, and full-featured benchtop instruments for laboratory environments. All models available in Australia with local support and calibration services.
Salinity meters — also called salt meters or NaCl testers — are...
Salinity meters — also called salt meters or NaCl testers — are precision instruments that measure the concentration of dissolved salts in water and liquid samples. Whether you’re managing a saltwater aquaculture pond, testing a pool’s salt-chlorinator system, monitoring seawater quality, or ensuring food products meet sodium specifications, the right salinity meter delivers fast, accurate results in the field or laboratory.
Pacific Sensor Technologies offers a comprehensive range of salinity testing solutions across all form factors: pocket-sized pen testers for quick spot checks, portable meters with data-logging capability for field surveys, analogue and digital refractometers for seawater and food applications, and full-featured benchtop instruments for laboratory environments. All models available in Australia with local support and calibration services.

pH, ORP, Conductivity, TDS, Salt, Temperature Met…

Conductivity, TDS, Salt, Temperature Meter

pH/mV/Cond/TDS/Salt/Temp Meter

pH/mV/Cond/TDS/Salt/Temp Meter, stores and recall…

Salinity Refractometer for sea water density with…

Conductivity / TDS / NaCl / Temperature MAX Porta…

Conductivity / TDS / NaCl / Temperature Laborator…

pH/ ORP/ Conductivity/ TDS/ NaCl/ Temp

Digital Refractometer for Sodium Chloride Measure…

Digital Refractometer for Seawater Measurements

Salinity Refractometer for sea water density with…

Salinity Refractometer for sea water density with…
A refractometer measures salinity optically — by bending light through a liquid sample — rather than electrically like a conductivity-based salinity meter. This makes refractometers the preferred choice for marine aquarium keepers, seawater analysis, and food-grade NaCl testing, where a drop of sample and a quick eyepiece or digital reading is faster than probe-based measurement. Our range covers both optical and digital formats: the MR100ATC (0–100% salinity, wide-range optical) and MR110ATC (0–10% salinity, fine-resolution optical) both include Automatic Temperature Compensation (ATC) for accurate readings without a warm-up period, while the MR128ATC is purpose-built for sea water density. For digital precision, the Milwaukee MA887 gives a direct digital salinity readout for seawater and aquarium use, and the Milwaukee MA886 is calibrated specifically for sodium chloride (NaCl) measurement in food and brine applications.
A salinity meter measures the concentration of dissolved salts (primarily sodium chloride) in water or liquid samples. Common applications include aquaculture pond management, pool and spa salt-chlorinator testing, food and beverage quality control, seawater analysis, and environmental water quality monitoring.
Quality digital salinity meters typically achieve an accuracy of ±0.1–0.5% NaCl or ±0.1–1 ppt, depending on the model and range. Bench-top laboratory meters offer higher accuracy than pocket pen testers. Regular calibration with a certified NaCl standard solution maintains measurement traceability.
A salinity meter uses an electrode to measure salinity electrically (via conductivity), while a refractometer measures it optically by reading how light bends through a liquid sample. Refractometers are typically preferred for marine aquariums, sea water density checks, and food-grade NaCl testing, where a quick drop-and-read sample is more practical than a probe. See our salinity refractometer range above for optical and digital options.
Most salt-chlorinator manufacturers recommend a pool salinity of 3,000–5,000 mg/L (ppm) of sodium chloride. Testing with a calibrated salinity meter every 2–4 weeks ensures the system operates efficiently and prevents equipment damage from salt imbalance.
Yes. Regular calibration using a certified NaCl reference solution ensures your readings remain accurate. Most portable meters should be calibrated before each use or at a minimum weekly for critical applications. Pacific Sensor Tech offers calibration standards and a professional calibration service from our Australian laboratory.
Absolutely. Salinity meters are one of the most important instruments in aquaculture. They help farm managers maintain optimal salinity ranges for species such as prawns (15–25 ppt), oysters (20–30 ppt), and marine fish (30–35 ppt). Look for models with automatic temperature compensation (ATC) and a measurement range of 0–100 ppt.
Pacific Sensor Technologies supplies salinity meters across Australia with fast shipping from our local warehouse. Browse our full range online or call our team on 1300 662 720 for expert product recommendations tailored to your application.