Pacific Sensor Tech supplies 0-10V output transmitters and sensors for building management (BMS), HVAC and PLC applications. A 0-10V analogue voltage signal is simple to wire into controllers with voltage inputs and is common in HVAC and automation panels over shorter cable runs. Our programmable COMET transmitters convert temperature, relative humidity, CO2, dew point and pressure into a linear 0-10V signal.
Need the signal to travellonger distances or resist electrical noise? Compare our 4-20mA current-loop transmitters, or browse all sensors by measured value.
Pacific Sensor Tech supplies 0-10V output transmitters and sensors for building management (BMS),...
Pacific Sensor Tech supplies 0-10V output transmitters and sensors for building management (BMS), HVAC and PLC applications. A 0-10V analogue voltage signal is simple to wire into controllers with voltage inputs and is common in HVAC and automation panels over shorter cable runs. Our programmable COMET transmitters convert temperature, relative humidity, CO2, dew point and pressure into a linear 0-10V signal.
Need the signal to travellonger distances or resist electrical noise? Compare our 4-20mA current-loop transmitters, or browse all sensors by measured value.
Temperature and humidity probe with 0-10V output<...
Compressed air RH+T+Tdp sensor with 0-10V output<...
Temperature and humidity duct probe with 0-10V ou…
Temperature and Humidity duct probe with 0-10V ou…
Temperature transmitter with 0-10V output, adjust…
Temperature transducer with 0-10V output
Temperature transmitter with 0-10V output, LCD Di…
Duct mount temperature transmitter with 0-10V out…
Ambient temperature, relative humidity transmitte…
Barometric pressure transmitter – 0-10V out…
CO2 concentration transmitter with 0-1…
CO2 concentration transmitter with 0-1…
CO2 concentration transmitter with 0-1…
RTD (Pt100/Pt1000) temperature transmitters with a linear 0-10V output, field-programmable to your exact span. Ideal for HVAC zones, plant rooms and BMS temperature inputs. See the full temperature sensor range for probe options.
Dual-output 0-10V transmitters measuring relative humidity and temperature together, with dew-point output on selected models — suited to HVAC validation, storage and horticulture.
NDIR CO2 transmitters with 0-10V output for demand-controlled ventilation and indoor air quality, across 0–2000 /0–10000 ppm ranges.
0-10V pressure transmitters for barometric, duct and process pressure with selectable ranges and fast response.
Choose 0-10V for short cable runs and direct connection to BMS/PLC voltage inputs — it’s simple and low-cost.
Choose 4-20mA for long runs, high noise immunity and built-in fault detection. Many COMET models are available in both outputs — see our 4-20mA transmitters range.
0-10V transmitter converts a measurement — temperature, humidity, CO2 or pressure — into a proportional DC voltage between 0 and 10 volts, where 0 V is the bottom of the range and 10 V the top. Controllers, BMS and PLCs with voltage inputs read it directly.
Use 0-10V for short cable runs and direct connection to BMS/PLC voltage inputs; it is simple and inexpensive. Use 4-20mA for long cable runs, strong noise immunity and live-zero fault detection. Many COMET transmitters are available in both outputs, so you can match the signal to the installation.
Any controller, BMS module, PLC or datalogger with a 0-10V (or 0-5V) analogue voltage input. It is a common standard in HVAC and building-automation panels.
Yes — most COMET transmitters let you rescale the 0-10V range to your required measuring span and configure filtering, so the same unit suits many applications.
Yes. Dual-parameter COMET transmitters provide two independent 0-10V outputs, for example relative humidity and temperature (or dew point), from a single device.
Yes. Pacific Sensor Tech ships 0-10V transmitters and sensors Australia-wide, with local technical support on range and probe selection.