COMET sensors and data loggers with dry contact (two-state) inputs – so one device monitors both the environment and the status of the equipment in it. Wire in a door switch, flood detector, pump fault or run signal alongside temperature, humidity or pressure, over PoE, Ethernet or RS232. Full specifications and a wiring guide are below the product grid.

COMET sensors and data loggers with dry contact (two-state) inputs – so one...

  • COMET P8652 PoE temperature and humidity sensor with three dry contact inputs for door and status monitoring.

    COMET P8652 | PoE Temperature & Humidity Sensor with 3 Dry Contact Inputs

    0 - 0 reviews

    Web Sensor with PoE – two channels with binary …

    $ 565.00 Ex. GST
    Add to cart
  • COMET H0530 Ethernet ambient temperature sensor with three dry contact inputs and two relay outputs.

    COMET H0530 | Ethernet Temperature Sensor with 3 Dry Contact Inputs & 2 Relays

    0 - 0 reviews

    Ambient temperature and 3 x binary input with Eth…

    $ 989.50 Ex. GST
    Add to cart
  • COMET H3530 Ethernet temperature and humidity sensor with three dry contact inputs and two relay outputs.

    COMET H3530 | Ethernet Temperature & Humidity Sensor with 3 Dry Contact Inputs & 2 Relays

    0 - 0 reviews

    Thermometer hygrometer with Ethernet interface an…

    $ 1,115.56 Ex. GST
    Add to cart
  • COMET H3531 Ethernet temperature and humidity sensor on remote probe cable with three dry contact inputs and two relay outputs.

    COMET H3531 | Ethernet Temperature & Humidity Sensor with Dry Contact Inputs & Relays — Remote Probe

    0 - 0 reviews

    Thermometer Hygrometer with Ethernet interface an…

    Price range: $ 1,200.00 through $ 1,249.50 Ex. GST
    Select options This product has multiple variants. The options may be chosen on the product page
  • COMET H3531P Ethernet compressed-air temperature, humidity and dew point sensor with three dry contact inputs and two relay outputs.

    COMET H3531P | Ethernet Compressed-Air Temperature, Humidity & Dew Point Sensor with Dry Contact Inputs & Relays

    0 - 0 reviews

    Compressed-air thermometer hygrometer with Ethern…

    Price range: $ 1,505.00 through $ 1,565.00 Ex. GST
    Select options This product has multiple variants. The options may be chosen on the product page
  • COMET H3531R rack-mount Ethernet temperature and humidity sensor with three dry contact inputs and two relay outputs.

    COMET H3531R | Ethernet Temperature & Humidity Sensor with Dry Contact Inputs & Relays — Rack-Mount

    0 - 0 reviews

    Rack mount thermometer hygrometer with Ethernet i…

    Price range: $ 1,265.00 through $ 1,319.50 Ex. GST
    Select options This product has multiple variants. The options may be chosen on the product page
  • COMET H4531 Ethernet temperature sensor for Pt1000 probes with three dry contact inputs and two relay outputs.

    COMET H4531 | Ethernet Pt1000 Temperature Sensor with 3 Dry Contact Inputs & 2 Relays

    0 - 0 reviews

    Thermometer with Ethernet interface and relays, f…

    $ 965.00 Ex. GST
    Add to cart
  • COMET H4531R rack-mount Ethernet temperature sensor for Pt1000 probes with three dry contact inputs and two relay outputs.

    COMET H4531R | Ethernet Pt1000 Temperature Sensor with Dry Contact Inputs & Relays — Rack-Mount

    0 - 0 reviews

    Rack mount thermometer with Ethernet interface an…

    $ 982.22 Ex. GST
    Add to cart
  • COMET H3331 RS232 temperature and humidity regulator with three dry contact inputs and relay outputs.

    COMET H3331 | RS232 Temperature & Humidity Regulator with 3 Dry Contact Inputs

    0 - 0 reviews

    Temperature and humidity regulator with RS232 out…

    Price range: $ 929.44 through $ 987.78 Ex. GST
    Select options This product has multiple variants. The options may be chosen on the product page
  • COMET H4331 RS232 temperature transmitter for Pt1000 probes with three dry contact inputs and relay outputs.

    COMET H4331 | RS232 Pt1000 Temperature Transmitter with 3 Dry Contact Inputs & Relays

    0 - 0 reviews

    Temperature transmitter with RS232 output

    $ 637.50 Ex. GST
    Add to cart
  • COMET H7531 Ethernet temperature, humidity and barometric pressure transmitter with three dry contact inputs, relay outputs and remote probe.

    COMET H7531 | Ethernet Temperature, Humidity & Barometric Pressure Transmitter with Dry Contact Inputs & Relays — Remote Probe

    0 - 0 reviews

    Thermometer hygrometer barometer with Ethernet in…

    Price range: $ 1,375.00 through $ 1,435.00 Ex. GST
    Select options This product has multiple variants. The options may be chosen on the product page
  • COMET U6841 4-channel current data logger with three 0-20mA current inputs and one dry contact input.

    COMET U6841 | 4-Channel Current Data Logger (3x 0-20mA + 1x Dry Contact Input)

    0 - 0 reviews

    Data logger for 3 current inputs 0-20mA and 1 two…

    $ 703.50 Ex. GST
    Add to cart
  • COMET U7844 four-channel data logger with two pulse inputs and two dry contact inputs.

    COMET U7844 | 4-Channel Pulse Data Logger (2x Pulse + 2x Dry Contact Inputs)

    0 - 0 reviews

    Four channel data logger with 2 x pulse and 2 x b…

    $ 703.50 Ex. GST
    Add to cart
  • COMET U7844G four-channel 4G data logger with two pulse inputs, two dry contact inputs and a built-in modem.

    COMET U7844G | 4-Channel Pulse 4G Data Logger (2x Pulse + 2x Dry Contact Inputs)

    0 - 0 reviews

    IoT Wireless Four channel Datalogger with pulse a…

    $ 1,559.50 Ex. GST
    Select options
  • COMET P8653 PoE temperature and humidity sensor with LD-81 flood detector and three dry contact binary inputs.

    COMET P8653 | PoE Temperature & Humidity Sensor with Flood Detector & 3 Dry Contact Inputs

    0 - 0 reviews

    Web Sensor with PoE, two channels with flood dete…

    $ 659.50 Ex. GST
    Add to cart
  • COMET H7530 Ethernet temperature, humidity and barometric pressure transmitter with three dry contact inputs and two relay outputs.

    COMET H7530 | Ethernet Temperature, Humidity & Barometric Pressure Transmitter with Dry Contact Inputs & Relays

    0 - 0 reviews

    Ethernet interface and Relays

    $ 1,317.00 Ex. GST
    Add to cart
  • COMET H0430 RS485 ambient temperature transmitter with three dry contact inputs and two relay outputs.

    COMET H0430 | RS485 Temperature Transmitter with 3 Dry Contact Inputs & 2 Relays

    0 - 0 reviews

    Temperature transmitter and regulator with RS485 …

    $ 839.50 Ex. GST
    Add to cart
  • COMET H3430 RS485 temperature and humidity transmitter with three dry contact inputs and two relay outputs.

    COMET H3430 | RS485 Temperature & Humidity Transmitter with 3 Dry Contact Inputs & 2 Relays

    0 - 0 reviews

    Temperature and humidity regulator with RS485 out…

    $ 1,035.00 Ex. GST
    Add to cart
  • COMET H3431 RS485 temperature and humidity transmitter on remote probe cable with three dry contact inputs and two relay outputs.

    COMET H3431 | RS485 Temperature & Humidity Transmitter with Dry Contact Inputs & Relays — Remote Probe

    0 - 0 reviews

    Temperature and humidity regulator with RS485 out…

    $ 1,089.56 Ex. GST
    Add to cart
  • COMET H4431 RS485 temperature transmitter for Pt1000 probes with three dry contact inputs and two relay outputs.

    COMET H4431 | RS485 Pt1000 Temperature Transmitter with 3 Dry Contact Inputs & 2 Relays

    0 - 0 reviews

    Temperature transmitter with RS485 output

    $ 759.50 Ex. GST
    Add to cart
  • What is a dry contact sensor?

    A dry contact – also called a volt-free or potential-free contact – is a switch that carries no voltage of its own. It simply opens or closes a circuit, and the monitoring device supplies the sensing voltage. That electrical isolation is the point: a door switch, float switch, pump relay or alarm panel can report its state to your monitoring system without any shared power between the two circuits.

    A dry contact is one of three signal types these inputs accept. Every COMET device on this page has one to three binary inputs, and each will take:

    • A dry (volt-free) contact – a relay, reed switch or mechanical switch with no voltage of its own.
    • An open-collector output – as found on many PLCs, counters and controllers.
    • A two-state voltage signal – logic low 0 to +0.5 V, logic high +3.0 to +30 V, so a 5 V, 12 V or 24 V status line connects directly.

    So if your equipment already provides a run, fault or alarm signal – as a contact or as a voltage – it can be wired straight in. Rather than buying a separate contact monitor, you connect it to a sensor you were already installing, and read temperature, humidity and equipment state on the same web page, SNMP trap or Modbus TCP register.

    PoE dry contact sensors

    The COMET P8652 and P8653 are powered and networked over a single Ethernet cable. Each carries three dry contact inputs alongside its temperature and humidity probes, so a comms rack, server room or plant room gets climate monitoring and door, flood or fault status from one PoE drop and one IP address.

    Most competing PoE dry contact sensors monitor contacts and nothing else. These measure as well – which usually removes a second device, a second cable run and a second switch port from the job.

    What you can monitor with a dry contact input

    Door and access status. Pair any sensor here with the COMET SA200A magnetic door contact to log and alarm on cabinet, cold room or comms room door openings.

    Flood and leak detection. The COMET P8653 ships with the LD-81 flood detector wired to its first input, with two inputs left free. This is water presence detection for plant rooms, raised floors and risers — not domestic smart-home leak alarms.

    Power presence and mains failure. A UPS, distribution board or generator changeover panel almost always provides a volt-free contact for mains-present or on-battery status. Wiring it to an input means a power event and the temperature rise that follows it appear on the same trend — which is usually how you find out a comms room lost cooling rather than lost power.

    Equipment run and fault signals. Most plant already offers a volt-free contact for run, fault or alarm status. Wiring it to a spare input puts machine state on the same trend as the environment it sits in.

    Beyond those, an input will accept the contact from almost any third-party device you already have on site — a smoke or fire panel’s auxiliary relay, an airflow or pressure switch, a float switch, a glass break or intruder detector, a filter differential-pressure switch, or a gate or barrier position switch. COMET sensors monitor and report these contacts; the detectors themselves are supplied by their own manufacturers.

    Dry contact inputs or relay outputs – which do you need?

    These are opposite directions and it is worth being certain which way your signal flows.

    A dry contact input lets the sensor read the state of something else – a door, a float switch, a pump’s fault contact. That is what the products on this page do.

    A relay output lets the sensor switch something else – a fan, a heater, a dehumidifier, an alarm beacon – when a reading crosses a threshold. For that, see our sensors with relay outputs.

    Most COMET Ethernet websensors on this page do both: three dry contact inputs for reading, two relay outputs for switching.

    Choose-by-connectivity

    Connectivity Binary inputs Models Best for
    PoE 3 P8652, P8653 Comms racks and server rooms — power and data on one cable, one IP address. P8653 ships with the LD‑81 flood detector on its first input.
    Ethernet 3 H0530, H3530, H3531, H3531P, H3531R, H4531, H4531R, H7530, H7531, P8552 Plant rooms and buildings on an existing LAN — SNMP, Modbus TCP and a browser interface. All except P8552 add two relay outputs so they can switch as well as read.
    RS485 / Modbus RTU 3 H0430, H3430, H3431, H4431, H7430 Multi‑drop serial runs into a PLC or SCADA head end, with two relay outputs on each unit.
    RS232 3 H3331, H4331 Direct serial connection to a single PC, PLC or existing host system.
    Standalone logging 1–2 U6841, U7844, U7844G Unattended sites with no network. U6841 adds three 0–20 mA inputs; U7844 adds two pulse inputs; U7844G adds a built‑in 4G modem for remote reporting.
    Contact device SA200A The magnetic door contact itself — wires into any binary input above to monitor cabinet, cold room or comms room doors.

    Every binary input above accepts three signal types: a dry (volt‑free) contact, an open‑collector output, or a two‑state voltage signal — logic low 0 to +0.5 V, logic high +3.0 to +30 V. The inputs are not galvanically isolated and the minimum pulse duration is 500 ms, so they monitor status rather than count fast pulses; for pulse counting use the U7844 or U7844G.

    Frequently Asked Questions

    What is a dry contact sensor?

    A dry contact sensor monitors a switch that carries no voltage of its own - it only opens or closes a circuit. The sensor supplies the sensing voltage and reports the state as open or closed. COMET sensors on this page have one to three binary inputs, so they read door switches, float switches and equipment fault contacts alongside temperature and humidity.

    Do these inputs only accept dry contacts?

    No. A dry contact is one of three signal types each binary input accepts. You can connect a dry (volt-free) contact, an open-collector output such as those on many PLCs and controllers, or a two-state voltage signal - logic low 0 to +0.5 V and logic high +3.0 to +30 V. That means an existing 5 V, 12 V or 24 V status line wires in directly, with no interposing relay needed.

    What is the difference between a dry contact and a volt-free or potential-free contact?

    Nothing - they are three names for the same thing, along with binary input, two-state signal and contact closure. COMET specification sheets use the term two-state signal; Australian and UK electrical practice usually says volt-free contact. All describe an isolated switch with no voltage of its own.

    How many binary inputs do these sensors have?

    The COMET Ethernet and PoE websensors and the RS232 models each have three. The U6841 data logger has one alongside three 0-20 mA current inputs, and the U7844 and U7844G have two alongside two pulse
    inputs. Note that on the H-series the inputs are not galvanically isolated, and the minimum pulse duration is 500 ms - so these monitor status rather than count fast pulses. For pulse counting, see the U7844 and U7844G.

    What is the difference between a dry contact input and a relay output?

    An input reads the state of something else; an output switches something else. Products on this page read door switches, float switches and fault contacts. If you need the sensor to switch a fan, heater or alarm when a reading crosses a threshold, see our sensors with relay outputs - most COMET Ethernet websensors do both.

    Can I monitor a door with these sensors?

    Yes. Wire the COMET SA200A magnetic door contact - or any existing volt-free door switch - to a spare input. The sensor then logs and alarms on door state on the same web interface as the temperature and humidity
    readings.

    Can these sensors detect water or flooding?

    The COMET P8653 includes the LD-81 flood detector, connected to its first input, leaving two free. This is water-presence detection for plant rooms, raised floors and risers, not a domestic leak alarm.

    Do the PoE models need a separate power supply?

    No. The P8652 and P8653 draw power and carry data over one Ethernet cable from a standard PoE switch or injector, so a rack or server room needs a single drop for climate and status monitoring.