MadgeTech RHTemp1000 | Temperature and Humidity Data logger

Built for use in harsh environments, MadgeTech RHTemp1000 records temperature from -40 °C to +80 °C alongside relative humidity. Compact and self-contained, it suits long-term monitoring in cold storage, warehouses, and industrial facilities where robust construction and a wide operating range are critical for dependable environmental data collection and compliance recordkeeping.

$ 1,149.75 Ex. GST

1 READY TO SHIP

Availability Info ?
1 AVAILABLE
1 READY TO SHIP, Leaves same day if ordered before 2pm AEST business days.
Need more than 1 item?
Order now and any extra items will be placed on backorder.
Available to back order. ETA will be 4 - 6 weeks.
IFC400 Interface is required to operate this device:
Calibration:

2 standard points each : Temperature (above 0°C) & Humidity

Call us on 1300 662 720 for a quote

Order total:

$1,149.75 Ex. GST

Description

The RHTemp1000 is a compact, humidity and temperature data logger, ideal for use in harsh environments.

This device measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C. The RHTemp1000 can store up to 16,384 time and date stamped readings, and is able to be programmed to start up to 24 months in advance.

The RHTemp1000 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

Other Models Available: RHTemp1000IS  RHTemp1000Ex

Specifications

General

Memory 32,768 readings (all channels enabled)
Reading Rate 1 reading every second up to 1 reading every 24 hours
Battery Life 2 years typical at 25 °C, 15 minute reading intervals
Material 316 Stainless Steel/Radel
Dimensions 1.7 in x 0.97 in x 0.97 in (42 mm x 24.6 mm x 24.6 mm)
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 100 %RH (non-condensing)
Required Interface Package IFC400 or IFC406
Approvals CE

 

Temperature

Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution 0.01 °C (0.018 °F)
Temperature Response
Time in Air
t63 – 8 minutes to 63% of change
t90 – 68 minutes to 90% of change
Temperature Calibrated Accuracy ±0.5 °C (0 °C to +55 °C)

 

Humidity

Humidity Sensor Capacitive Polymer
Humidity Range 0 %RH to 100 %RH (non-condensing)
Humidity Resolution 0.1 %RH
Humidity Response
Time in Air
t90 – 2 minutes to 90% of change
Humidity Calibrated Accuracy ±3 %RH maximum
Humidity Specified Accuracy Range 25 %RH to 75 %RH
+20 °C to +40 °C
Hysteresis Error 1 % Typical, 3% Maximum.

Reviews
Leave your review
Rating

Register Your Interest