MadgeTech UltraShock records shock and acceleration data across an operating temperature range of -20 °C to +60 °C and up to 95% RH. Suited to transport validation, drop testing, and impact analysis, it captures combined shock and environmental condition data simultaneously, providing a complete picture of dynamic events throughout handling and logistics cycles.

$ 2,408.50 Ex. GST

Available to back order. ETA will be 4 - 6 weeks.

Availability Info ?
Available to back order. ETA will be 4 - 6 weeks.

$2,408.50 Ex. GST

Description

The new UltraShock contains powerful improvements and an all-in-one functionality, allowing it to replace all current shock models and their capabilities. New refinements also include a smaller, lighter design and LED status indicators.

Additional features include a significantly improved battery life and the use of a USB-C cable, making it easily rechargeable. Each UltraShock purchase contains an AC adapter and USB cable, eliminating the need for an additional interface cable.

The UltraShock is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

The UltraShock replaces the UltraShock Legacy and the TSR101.

Specifications

General

Memory 3,593,358 readings
(598,893 per channel, all channels in use)
Reading Rate 1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure & humidity sampled approx. every
2 seconds at intervals shorter than
2 seconds. Otherwise, sampled at the reading rate.
Battery Life 90 days typical at 64Hz rate
Material Anodized aluminum
Dimensions 3.4 in x 1.7 in x 1.3 in
(86 mm x 43 mm x 33 mm)
Operating Environment -20 ºC to +60 ºC,
0 %RH to 95 %RH non-condensing
Required Interface Package USB-C cable required (included); 1MBaud
Approvals CE compliant
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
IP Rating 64

 

Temperature

Sensor Semiconductor
Range -20 ºC to +60 ºC
Resolution 0.1 ºC
Accuracy ±0.5 ºC (+5 ºC to +60 ºC)

 

Humidity

Sensor Capacitive Polymer
Range 0 %RH to 95 %RH
Resolution 0.1 %RH
Calibrated Accuracy ±3 %RH (±2 %RH typical at 25 ºC)
Specified Accuracy Range +20 °C to +40 °C; 20 %RH to 80 %RH

 

Pressure

Sensor Semiconductor Strain Gage
Range 100 mbar to 1300 mbar
Resolution 0.05 mbar
Calibrated Accuracy ±1.5 mbar at 25 ºC; at 750 mbar

 

Shock

Accelerometer Type MEMS Semiconductor
Acceleration Range (g) ±15 g/±100 g/±300 g
Acceleration Resolution (g) 0.02 g/0.05 g/0.2 g
Calibrated Accuracy (g) ±0.3 g/±2.0 g/±6.0 g
Sampling Rate 1000 Hz
Accelerometer Freq. Resp. >1000 Hz (15 g)
>500 Hz (100 g, 300 g)
Reading Rate 1024 Hz to 5 minutes for shock, selectable in software. Temperature, pressure & humidity sampled approx. every
2 seconds at intervals shorter than
2 seconds. Otherwise, sampled at the reading rate.